Skip to main content

Plastic Fabricators

INDUSTRIAL CORROSION PROTECTION

LABORATORY FUME HOOD

Manufactured by Plastic Fabricators

Daily activities in any laboratory involve a variety of chemicals. As these chemicals are mixed, heated, tested, sampled or analyzed, they may produce vapors, fumes or airborne particulates which must not remain in the work place. Laboratory Fume Hoods ensure that these emissions are contained and released safely into the exhaust system, thus making the work atmosphere safe for lab technicians.

Plastic Fabricators designs and produces Laboratory Fume Hoods for research laboratories, pharmaceutical industries, chemical industries, educational institutes, quality control labs and other industrial testing centers. These hoods are made in such a way that they offer effective containment along with convenient accessibility to the work area. The various models we manufacture are Full Polypropylene (PP) Fume Hoods, Wooden + PP Combination Fume Hoods and MS Powder Coated Fume Hoods. Each model has a counterbalanced toughened glass sash, chemically resistant inner work surface, utilities and exhaust system.

25+
Years of Experience
38×38mm
Mesh Box Size
ZERO
Scrap Value
3
Grating Types
TECHNICAL DATA

WHAT IS A LABORATORY FUME HOOD?

Laboratory Fume Hood is an enclosure that ensures protection of laboratory personnel from the hazards posed by the harmful fumes, vapors, gases, and airborne particles produced in laboratory activities.

A laboratory fume hood functions by drawing air through its front face, across the work surface, and out through the exhaust system. This way, the enclosure provides a means to control the air flow within it thus containing the airborne hazards and preventing them from escaping into the laboratory.

Unlike typical workstations, laboratory fume hood creates a zone for laboratory personnel to perform their duties safely under the ventilation conditions. Depending on how it is used, the fumes may be discharged to atmosphere or first passed through pollution control equipment such as PP FRP Scrubber.

Each Laboratory Fume Hood produced by Plastic Fabricators incorporates characteristics ensuring chemical resistance, safety of operators and easy maintenance of the system. Counter-balanced toughened glass sashes, chemical resistant work walls and options of gas, water, and utility connections enable the system to serve routine laboratory as well as industrial purposes.

Why Industries Choose Laboratory Fume Hoods

🛡️
Effective Fume Containment The fume hood keeps drawing the polluted air away from the operator towards the exhaust system, thereby minimizing exposure to the chemical vapors released in the laboratory.
🪟
Counter-Balanced Toughened Glass Sash Every laboratory fume hood is fitted with a vertically moving counterbalanced toughened glass sash which moves smoothly and offers clear visibility of the operating area. The toughened glass has increased strength as compared to the normal glass.
🧪
Chemical-Resistant Interior The interior working space has been constructed using material that can withstand spills, splashing, and contact with many laboratory chemicals, hence making the hood appropriate for laboratory work.
📦
Multiple Material Options Each lab has different needs. The products provided by Plastic Fabricators are: Fully Polypropylene (PP) Fume Hoods, Wood & PP Combo Fume Hoods, and MS Powder Coated Fume Hoods. This enables the customer to choose the best construction material that suits them.
🔧
Custom Utility Integration The gas valves, water fittings, sinks, power connections, nozzles, and other utilities for the laboratory may be installed within the hood per the specific customer requirements.
🌬️
Complete Ventilation Solution In addition to the fume hood, Plastic Fabricators can supply PP/FRP Exhaust Ducting, Direct Drive Fans, PP FRP Scrubbers, Chimneys, Ventilation Systems, and System Installation and Commissioning. Having all of these components supplied by one manufacturer streamlines the project and ensures compatibility of all elements of the package.
TYPES OF LABORATORY FUME HOODS​

OUR LABORATORY FUME HOODS

All laboratories are not the same. A quality control laboratory in a pharmaceutical industry will have different ventilation requirements from a chemical research laboratory or educational laboratory. The chemicals used, frequency of usage, utilities needed, and space available will determine the design of the fume hood.

Plastic Fabricators provides customized Laboratory Fume Hoods that have a focus on operator safety, chemical resistance, and ease of operation. All hoods are designed with a view of maintaining optimum air flow and giving users a practical and comfortable working environment.

Depending on whether the requirement is a small laboratory desk or an entire system of connected fume hoods, all are fabricated based on the layout and requirements of the customer’s laboratory. We also offer exhaust solutions comprising PP/FRP ducting, Direct Drive Blowers, PP FRP Scrubbers, Chimneys, and commissioning services, thereby offering a single-stop shop for a customer to purchase the entire ventilation system.

DESIGN FEATURES

Counter-Balanced Toughened Glass Sash

The vertically sliding front sash is manufactured from toughened glass and operates using a counter-balanced mechanism.

This provides:

  • Smooth operation
  • Clear visibility
  • Improved safety of the operator
  • Ease of access to the work area
  • Working opening

The counter-weighting system decreases operator’s effort and allows sash stability at multiple levels.

Chemical-Resistant Interior

The interior work chamber is built from chemically resistant material which makes it capable of withstanding exposure to laboratory chemicals, acids, and alkalis.

Smooth interior surface eases regular cleaning process and reduces chemical residue build-up.

Integrated Utility Connections

Depending on the requirements of the laboratory, the hood can be provided with:

  • Gas Valves
  • Water Taps
  • Laboratory Sink
  • Electrical Sockets
  • Service Nozzles
  • Drain Connection
  • Utility Panels
  • Arrangement of above utilities can be customized according to the laboratory workflow.

The layout of these utilities can be customized according to laboratory workflow.

Efficient Airflow Design

The airflow design is intended to extract fumes generated inside the work chamber and direct them to the exhaust system.

Correctly designed air pattern helps in minimizing the contamination by airborne contaminants.

Multiple Construction Options

To suit different laboratory environments, Plastic Fabricators offers:

  • Polypropylene (PP) full plastic
  • Combination wooden and PP
  • MS Powder Coated Construction
  • Based on chemicals used, durability requirements and customer’s preference.

Each option is selected based on the chemicals handled, durability requirements, and customer preferences.

01
WHERE WE APPLY FRP

Full Polypropylene (PP) Fume Hood

Description

This particular type of fume hood is completely manufactured using polypropylene, which does not get corroded easily. This kind of hood is suitable for laboratories dealing with aggressive acids and corrosive chemicals. The inner surfaces are easy to clean, and resistant to chemical corrosion.

Ideal For
  • Acid Labs
  • Chemical Plants
  • Electroplating Labs
  • Pharmaceutical Companies
  • Chemical R&D Departments
Benefits
  • High resistance to chemicals
  • Highly resistant to corrosion
  • Easy cleaning
  • Durability
  • Minimal maintenance
02
WHERE WE APPLY FRP

Wooden + PP Combination Fume Hood

Description

In this fume hood, the outer shell of the hood is made of wood, while the inner surface of the work chamber is coated with polypropylene.

Suitable For
  • Educational Institutions
  • Research Institutions
  • Quality Control Labs
  • General Chemical Labs

Here, the polypropylene lining gives protection inside the fume hood and the wooden body outside.

Benefits ​
  • High resistance to chemicals
  • Highly resistant to corrosion
  • Easy cleaning
  • Durability
  • Minimal maintenance
03
WHERE WE APPLY FRP

MS Powder-Coated Fume Hood

Description

In those labs where mechanical stability is more essential than chemical stability, one can use this particular type of fume hood. The body of this fume hood is made up of MS powder-coated steel.

Common Applications
  • Industrial Laboratories
  • Production Quality Control Laboratories
  • Pilot Plants
  • Testing Centers

The powder-coated finish improves durability while maintaining a professional appearance.

Benefits
  • High resistance to chemicals
  • Highly resistant to corrosion
  • Easy cleaning
  • Durability
  • Minimal maintenance
Applications

WHERE LABORATORY FUME HOODS ARE USED

The Plastic Fabricators Laboratory Fume Hoods are used in numerous types of buildings, where fumes and chemical vapors are produced in the course of regular activities.

Typical applications include:

  • Chemical Laboratories
  • Pharmaceutical Laboratories
  • Research and Development Labs
  • Quality Control Laboratories
  • Educational Establishments
  • Biotechnology Laboratories
  • Food Testing Laboratories
  • Environmental Laboratories
  • Petrochemical Laboratories
  • Paint and Coating Laboratories
  • Universities and Colleges
  • Industrial Test Facilities
  • Government Research Organizations
  • Analytical Laboratories

 

Whatever purpose they are used for, proper fume hoods provide additional safety and control within the lab.

ORDERING REFERENCE

HOW A LABORATORY FUME HOOD WORKS ?

Controlled Airflow for Laboratory Safety

A Laboratory Fume Hood operates by creating a controlled airflow that captures contaminants before they spread into the laboratory.

The process generally works as follows:

Step 1 – Fresh Air Enters

The air from the laboratory moves through the front opening of the hood.

Step 2 – Hazardous Vapours Are Captured

While conducting experiments in the enclosure, the dangerous fumes and vapours are extracted away from the user and not allowed to move into the laboratory.

Step 3 – Air Moves Through the Hood

The air flow will pass in a uniform manner through the working chamber to the exhaust ducts.

Step 4 – Exhaust System Removes Contaminants

According to how the system has been installed, the air can:

  • Be discharged to the outside environment
  • Go through a PP FRP Scrubber
  • Be connected to the exhaust system of the laboratory

SPECIFICATION APPROACH

Each laboratory will have its own ventilation and operational needs. The chemicals that are being used, the design of the laboratory, utility services, and the design of the exhaust system all play roles in determining the design of the Laboratory Fume Hood.

Plastic Fabricators produces both standard as well as customized Laboratory Fume Hoods for use in research laboratories, pharmaceutical companies, chemical companies, educational institutions, and industrial testing laboratories.

Feature Specification
Available Construction Full PP, Wooden + PP, MS Powder-Coated
Front Sash Counter-Balanced Toughened Glass
Work Surface Chemical Resistant
Utility Options Gas, Water, Electrical, Sink, Drain
Exhaust Connection Top Outlet
Airflow Design Negative Pressure Ventilation
Installation Floor Mounted
Custom Sizes Available
Complete Exhaust System Optional
Designed for Continuous Industrial Ventilation

WHY A PROPERLY DESIGNED FUME HOOD MATTERS?

A Laboratory Fume Hood is one of the most critical safety items found in every chemical laboratory.

Chemicals used during normal lab work can emit fumes that could pose dangers if permitted to disperse freely within the lab. A good design allows the fume hood to collect these emissions and vent them through an exhaust system.

In addition to ensuring safe operation, a good fume hood will also allow you to:

  • Keep your lab cleaner
  • Reduce dangerous fume exposure
  • Ensure more comfortable lab work
  • Protect laboratory equipment from corrosive fumes
  • Adhere to lab safety standards

In conjunction with the right exhaust fan, ductwork, and air pollution control equipment, a Laboratory Fume Hood forms part of a laboratory ventilation system.

CUSTOM FABRICATION SERVICES

COMPLETE LABORATORY EXHAUST SOLUTIONS

Plastic Fabricators supplies full laboratory exhaust systems where all the required components can be obtained from one source.

Our complete systems can include:

  • Laboratory Fume Hood
  • PP/FRP Ducting
  • Direct Drive Blower
  • PP FRP Scrubber
  • Exhaust Stack / Chimney
  • Utilities
  • Control Panels

A complete system ensures proper compatibility between equipment and simplifies installation, maintenance, and future expansion.

CUSTOM MANUFACTURING

Our Range of Laboratory Fume Hoods Is Tailored Based On
  • ✓Laboratory Floor Plan
  • ✓Chemical Types
  • ✓Operator Strength
  • ✓Utility Needs
  • ✓Airflow Needs
  • ✓Exhaust System Needs
  • ✓Space Available for Installation
  • ✓Safety Needs
Customisation Options
  • ✓Fully Plastic Construction
  • ✓Composite Construction of Wood & Plastic
  • ✓Construction using MS with Powder Coating
  • ✓Single Operator
  • ✓Double Operator
  • ✓Walk-In Fume Hood
  • ✓Utility Panel Options
  • ✓Custom Lighting
  • ✓Storage Cabinets
  • ✓Mobile Base
  • ✓Special Dimensions

TECHNICAL SUPPORT

We Provide Full Technical Support

Our technical team is available to help you select the right profiles, verify load capacities, and confirm chemical compatibility for your specific application.

We Provide
  • ✓Load capacity calculations
  • ✓Material selection guidance
  • ✓Installation recommendations
  • ✓Chemical compatibility data
  • ✓Sample profiles for testing (charge applies)
Contact Us For
  • ✓Project quotations
  • ✓Technical questions
  • ✓Custom profile development
  • ✓Bulk order pricing
ORDERING INFORMATION

How to Order

Call or message us directly with your requirements. No complex procurement process just tell us what you need, and we will get back to you with pricing and availability. If you are looking for a new or replacement PP grid, send whatever information you have available.

Information Required
  • →Laboratory Application
  • →Type of Chemicals Used
  • →Preferred Construction (PP / Wooden + PP / MS)
  • →Hood Dimensions
  • →Number of Workstations
  • →Utility Requirements
  • →Exhaust Airflow
  • →Existing or New Exhaust System
  • →Installation Location
  • →Quantity Required
Example Enquiry
Request for supply of 1 (one) Polypropylene Full Laboratory Fume Hood for our QC lab. Dimensions approximately 1500mm wide with provision for gas & water utilities. This would connect to our PP FRP Exhaust Duct and Scrubber system. Can you please advise on the right model and give us a quotation?
Contact — Plastic Fabricators

Call or message for pricing, stock availability, technical data sheets, sample requests, and custom quotes.

All information accurate as of publication. Specifications subject to change with process improvements. Call to confirm current specifications for your application.

Ready to Order or Quote?

Call or message us directly. We provide load calculations, material selection guidance, chemical compatibility data, and sample profiles.