FRP grating is an option for chemical plants’ walkways which offers corrosion resistance instead of traditional metal grating due to the exposure of such areas to moisture, chemical spills, and fumes.
Fiber reinforced plastic is an advanced material consisting of glass fibers embedded in polymer resin to provide lightweight and structurally strong panels intended for walkways, platforms and industrial flooring.
For any chemical plant there is need for durable flooring which would stand up against the harsh operating environment of the facility. Choosing the best FRP grating requires understanding of its load-bearing capacity, chemical resistance, slip resistance, support distance and fire resistance properties.
This guide will cover the applications of FRP grating in chemical plants and how to choose one.
FRP grating, also known as fibre reinforced plastic grating, means grid panels made through glass fibres and resin.
The types include:
Moulded FRP Grating: It is made through a mixture of resin and fibres to make grid panels. The fibres used in this case are normally able to bear the weight in both directions of the panel.
Pultruded FRP Grating: It is made from load-bearing bars pultruded and put together to make the grid panels. Such panels normally have their focus on load bearing on the bearing bars.
Either type can be good for walkways in industries depending on various considerations.
Chemical processing environments can expose flooring systems to acids, alkalis, moisture, chemical vapours and cleaning solutions. Conventional steel grating may require corrosion protection and ongoing maintenance, depending on its environment.
FRP grating can be a suitable option when its material properties match the operating conditions.
Among the reasons why industrial sites prefer FRP grating is the anti-rusting ability of this product.
The reason why FRP grating does not rust is that this grating does not contain any carbon steel components, which can be corroded by water and cause rust. Also, FRP grating is able to withstand a wide variety of chemicals when choosing appropriate resins.
But the ability of FRP grating to resist all kinds of chemicals is not guaranteed.
A slip hazard can arise in a chemical plant due to moisture, process fluids, oil or any other chemical contamination.
This product can be provided with either textured or grit surface for better anti-slip performance.
It is necessary that the right kind of finish be chosen on the basis of conditions of use, foot wear, cleaning and possible contamination.
It would be prudent not to assume the slip resistance and have it determined and certified independently.
FRP grating is usually lighter than its counterpart steel grating, making it easier to handle and install. Lighter weight is an advantage that may assist in lowering the dead load on the support structure. However, the total walkway should be examined for live loads, point loads, span, and deflection.
Steel grating in corrosive surroundings might need coatings or inspection or even replacement of corroded parts.
Properly chosen FRP grating will eliminate the maintenance work that involves rust and paint deterioration. However, it still needs periodic inspection for cracks, impact damage, loose fastenings, UV damage and any other forms of deterioration.
FRP gratings have low conductivity when compared with metal gratings; this may be a benefit in certain industrial applications.
However, the lack of electrical conductivity cannot substitute for electrical safety guidelines on the construction site. Electrical properties of the chosen product need to be checked in case they are relevant for the application.
FRP grating can be considered for several areas of a chemical-processing facility, subject to engineering and chemical-compatibility checks.
| Application | Why FRP grating may be considered |
|---|---|
| Elevated walkways | Lightweight construction and corrosion resistance |
| Maintenance platforms | Access to equipment in corrosive environments |
| Chemical-processing areas | Potential resistance to compatible chemical exposure |
| Tank access platforms | Suitable options for industrial access structures |
| Wastewater-treatment facilities | Corrosion resistance in suitable operating conditions |
| Pump and equipment platforms | Open-grid construction and drainage |
| Industrial trenches and access covers | Options for removable panels and inspection access |
Both types have useful applications. The correct selection depends on the walkway design and operating conditions.
| Feature | Moulded FRP grating | Pultruded FRP grating |
|---|---|---|
| Manufacturing method | Reinforcement and resin are formed into a moulded grid panel | Pultruded bearing bars are assembled into a grating panel |
| Load-bearing behaviour | Generally carries loads in both panel directions | Primarily carries loads along the bearing bars |
| Typical use | General industrial walkways, platforms and access areas | Applications requiring directional stiffness or longer spans |
| Panel openings | Grid layout can accommodate some cut-outs with suitable engineering | Cutting bearing bars may interrupt a principal load path |
| Surface finish | Textured and grit-coated options may be available | Anti-slip surface options may be available |
| Selection priority | Panel construction, support spacing and load requirements | Bearing-bar direction, support spacing and load requirements |
There is no universally better type. Compare the manufacturer’s load tables and deflection limits for the actual span and loading conditions before selecting either option.
Explore FRP moulded grating and FRP pultruded grating from Plastic Fabricators.
Steel grating and FRP grating can both serve industrial flooring applications, but their characteristics differ.
| Factor | FRP grating | Carbon steel grating |
|---|---|---|
| Corrosion behaviour | Does not rust like carbon steel; chemical resistance depends on the resin | Can corrode without suitable protection |
| Weight | Generally lighter than comparable steel systems | Generally heavier |
| Maintenance | Can reduce corrosion-related maintenance | May require coating inspection and corrosion control |
| Electrical conductivity | Generally non-conductive | Conductive |
| Load capacity | Depends on panel design, reinforcement and span | Depends on steel section, grating construction and span |
| Fire performance | Must be verified for the specific product | Depends on the steel system and the wider installation |
| Initial cost | Varies by product and specification | Varies by steel grade, finish and design |
| Long-term cost | Depends on service life, installation and maintenance | Depends on corrosion protection, maintenance and replacement requirements |
The best material should be selected based on engineering requirements and total lifecycle cost not solely on initial purchase price.
Before purchasing FRP grating, evaluate the following factors.
The chemicals that would be exposed to the gratings include splashes, vapors, cleaning solutions, and spills that may take place. The compatibility of the resins should be checked against the chemical concentration, temperature, and duration of exposure.
Determine the expected loads, which are:
The load tables from the manufacturer will be able to accommodate the proposed span and panel configuration.
Choose an appropriate method for surface preparation based on whether the surface is expected to be wet or contaminated.
Think about the cleaning process of the walkway and the possibility that the residue can accumulate. Don’t forget to take into account any special footware requirements.
The panel depth, the size of the openings and the bearing bar layout affect performance and utility.
Dimensions should be chosen according to the load requirements, spacing of the supports, drainage, and safety of the site. The openings also need to conform to the specifications of the facility concerned.
The walkways in outdoor industrial chemical plants could be subjected to sunlight, rain, changes in temperature, and moisture.
Check the suitability of the product under UV radiation and environmental conditions at the site. Thermal expansion, support, and fixing must also be evaluated.
Some plant species have fire behavior standards which describe some aspects of fire behavior such as fire spread and smoke production.
It is recommended that you should refer to the project specifications as far as the details concerning this grating are concerned. It should be understood that all FRP gratings do not necessarily have similar fire behavior aspects.
Make sure you understand how the panels are to be mounted, secured, cut and tested.
Where there are cut-outs for pipes, equipment, or cables, extra supports may be required. Installation must be done according to the manufacturer’s instructions and the engineering design that has been approved.
In order to assist in recommending the proper grating for you, please provide the following:
A diagram that shows the layout of the walkway and location of the supports will be helpful.
Plastic Fabricators offers FRP moulded grating and FRP pultruded grating for industrial applications.
For chemical plant walkways, please supply information on loads, support spacing, operating conditions, chemical resistance, and surface-finish requirements regarding your project.
This information will assist in determining whether the proposed grating system will be suitable for your project.
The FRP grating can prove to be a good flooring material choice for walkways of chemical plants that need corrosion resistance, lightweight and lesser corrosion maintenance.
Moulded and pultruded grating both have their uses, but the selection of which one depends upon the loading, spacing of supports, chemical exposure and safety conditions.
It is important to confirm the load capacity, chemical resistance, anti-slip properties, weatherability and fire rating of the grating before buying it.
Plastic Fabricators supplies FRP moulded grating and FRP pultruded grating for industrial applications. Share your project requirements to discuss a suitable grating solution for your chemical plant.
WhatsApp us